NathanTools
NathanTools
Text Tools 13
SEO Tools 7
Image Tools 19
YouTube Tools 38
Device Tests 4
PDF Tools 10
Calculators 52
Electrical Calculators 10
Time Tools 7
Random Tools 9
Converters 14
Developer Tools 11
Hash Generators 5
Password & Security 2
Network & DNS 3
Website Tools 9

Wire Gauge Calculator

Pick a gauge, diameter or area to see its size in every unit, its resistance and the nearest AWG and SWG.

100% free No sign-up Works on any device

Updated November 2026 · Resistance for solid copper at 20 °C

How to use the wire gauge calculator

  1. Pick what you know: an AWG or SWG gauge, a diameter or a cross-section area.
  2. Read the equivalents: diameter in mm and inches, area in mm² and kcmil, copper resistance, and the nearest gauge in the other system.
  3. Browse the full AWG or SWG chart below. Your size is highlighted.

AWG formulas

d(mm) = 0.127 × 92^((36 − n) ÷ 39) A(mm²) = π ÷ 4 × d² R(Ω/km) = ρ ÷ A, ρ(copper) = 0.01724 Ω·mm²/m

Common uses by gauge

AWGTypical use (copper)
4/0 – 2Service entrance, large feeders, welding cable
6 – 8Ranges, dryers, EV chargers, sub-panels
1030 A circuits: water heaters, air conditioners
1220 A circuits: kitchens, bathrooms, outlets
1415 A circuits: lighting and general outlets
16 – 18Extension cords, lamp cords, speaker wire
22 – 24Electronics, Ethernet cable (Cat5e/Cat6), breadboards
28 – 30Ribbon cables, wire-wrap

Check that a size works over distance with the voltage drop calculator.

Frequently asked questions

American Wire Gauge, the standard for wire sizes in North America. Larger numbers mean thinner wire: 10 AWG is 2.59 mm across, 20 AWG is 0.81 mm. Every 6 gauges halves the diameter, and every 3 gauges roughly halves the area.

Diameter in mm = 0.127 × 92^((36 − n) ÷ 39), where n is the gauge. For 12 AWG that's 2.05 mm, or 3.31 mm² in area. Sizes above 1 AWG are written 1/0, 2/0, 3/0 and 4/0 (“one-aught” to “four-aught”), and use n = 0, −1, −2 and −3.

Standard Wire Gauge (also called British or Imperial wire gauge), defined in the UK in 1883 and still used for jewellery wire, guitar strings and some sheet metal. SWG and AWG numbers don't match: 18 SWG is 1.22 mm but 18 AWG is 1.02 mm.

It depends on the current, the length and the insulation rating, and your local code is the final word. As a rough guide for copper house wiring in the US: 14 AWG for 15 A circuits, 12 AWG for 20 A and 10 AWG for 30 A. Check long runs with the voltage drop calculator.

Metric cables are sold by cross-section area. 1.5 mm² is close to 16 AWG (1.31 mm²) and 2.5 mm² sits between 14 AWG (2.08 mm²) and 12 AWG (3.31 mm²). The calculator shows the nearest gauge for any area.
Esc
↑ ↓ to moveEnter to open